ODAK Corporation
Committed To Being the Industry Leader In a Leading Industry *Since 1979
The Ultimate In Residential, Commercial and Industrial
Sub-Micron Drinking Water Filtration Systems

HomeCorporate OverviewFilter ComparisonsWater ContaminantsFrequently Asked Questions
Performance Data SheetEmergency ResponseProduct ShowroomKentrel CorporationContact ODAK

PERFORMANCE DATA SHEET
For Model No. ODAK500B and ODAK500C
Manufactured by Multi-Pure Drinking Water Systems for ODAK Corporation

NSF/ANSI 53 - Health Effects

NSF LogoThe ODAK500 has been tested and certified under NSF/ANSI Standard Nos. 53 as shown below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 53, Health Effects.

Substance

Percent Reduction**

Influent Challenge Concentration
(mg/L unless specified)

Maximum Permissible Product Water Concentration
(mg/L unless specified)

ALACHLOR*

>98%

0.05

0.001

ASBESTOS

>99.9%

107 to 108 fibers/L;fibers greater than 10
micrometers in length

99% reduction requirement

ATRAZINE*

>97%

0.1

0.003

BENZENE*

>99%

0.081

0.001

BROMODICHLOROMETHANE (TTHM)*

>99.8%

0.300  +/-  0.30

0.015

BROMOFORM (TTHM)*

>99.8%

0.300  +/-  0.30

0.015

CARBOFURON (Furadan)*

>99%

0.19

0.001

CARBON TETRACHLORIDE*

98%

0.078

0.0018

CHLORDANE

>99.5%

0.04 +/- 10%

0.002

CHLOROBENZENE (Monochlorobenzene)*

>99%

0.077

0.001

CHLOROPICRIN*

99%

0.015

0.0002

CHLOROFORM (TTHM)* (surrogate chemical)

>99.8%

0.300 +/- 0.30

0.015

Cryptosporidium (CYST)

99.95%

minimum 50,000 m/L

99.95%

CYST (Giardia; Cryptosporidium; Entamoeba; Toxoplasma)

99.95%

Minimum 50,000 m/L

99.95%

2,4-D*

98%

0.110

0.0017

DIBROMOCHLOROMETHANE (TTHM; Chlorodibromomethane)*

>99.8%

0.300 +/- 0.30

0.015

DIBROMOCHLOROPROPANE (DBCP)*

>99%

0.052

0.00002

o-DICHLOROBENZENE (1,2 Dichlorobenzene)*

>99%

0.08

0.001

p-DICHLOROBENZENE (para-Dichlorobenzene)*

>98%

0.04

0.001

1,2 DICHLOROETHANE (1,2-DCA)*

95%

0.088

0.0048

1,1-DICHLOROETHYLENE (1,1-DCE)*

>99%

0.083

0.001

CIS-1,2-DICHLOROETHYLENE*

>99%

0.17

0.0005

TRANS-1,2-DICHLOROETHYLENE*

>99%

0.086

0.001

1,2-DICHLOROPROPANE (Propylene Dichloride)

>99%

0.08

0.001

CIS-1,3-DICHLOROPROYLENE*

>99%

0.079

0.001

DINOSEB*

99%

0.17

0.0002

ENDRIN*

99%

0.053

0.00059

ETHYLBENZENE*

>99%

0.088

0.001

ETHYLENE DIBROMIDE (EDB)*

>99%

0.044

0.00002

HALOACETONITRILES (HAN)*

 

 

 

     BROMOCHLOROACETONITRILE

98%

0.022

0.0005

     DIBROMOACETONITRILE

98%

0.024

0.0006

     DICHLOROACETONITRILE

98%

0.0096

0.0002

     TRICHLOROACETONITRILE

98%

0.015

0.0003

HALOKETONES (HK)*

 

 

 

     1,1-DICHLORO-2-PROPANONE

99%

0.0072

0.0001

     1,1,1-TRICHLORO-2-PROPANONE

96%

0.0082

0.0003

HEPTACHLOR*

>99%

0.25

0.00001

HEPTACHLOR EPOXIDE*

98%

0.0107

0.0002

HEXACHLOROBUTADIENE (Perchlorobutadiene)*

>98%

0.044

0.001

HEXACHLOROCYCLOPENTADIENE*

>99%

0.060

0.000002

LEAD (pH 6.5)

>99.3%

0.15 +/- 10%

0.010

LEAD (pH 8.5)

>99.3%

0.15 +/- 10%

0.010

LINDANE*

>99%

0.055

0.00001

MERCURY (pH 6.5)

>99%

0.006 +/- 10%

0.002

MERCURY (pH 8.5)

>99%

0.006 +/- 10%

0.002

METHOXYCHLOR*

>99%

0.050

0.0001

MTBE (methyl tert-butyl ether)

>96.6%

0.015 +/- 20%

0.005

POLYCHLORINATED BIPHENYLS (PCBs, Aroclor 1260)

>99.9%

0.01 +/- 10%

0.0005

PENTACHLOROPHENOL*

>99%

0.096

0.001

STYRENE (Vinylbenzene)*

>99%

0.15

0.0005

1,1,2,2-TETRACHLOROETHANE*

>99%

0.081

0.001

TETRACHLOROETHYLENE*

>99%

0.081

0.001

TOLUENE (Methylbenzene)*

>99%

0.078

0.001

TOXAPHENE

>92.9%

0.015 +/- 10%

0.003

2,4,5-TP (Silvex)*

99%

0.270

0.0016

TIRBROMOACETIC ACID*

 

0.042

0.001

1,2,4 TRICHLOROBENZENE (Unsymtrichlorobenzene)*

>99%

0.160

0.0005

1,1,1-TRICHLOROETHANE (1,1,1-TCA)*

95%

0.084

0.0046

1,1,2-TRICHLOROETHANE*

>99%

0.150

0.0005

TRICHLOROETHYLENE (TCE)*

>99%

0.180

0.0010

TRIHALOMETHANES (TTHM) (Chloroform; Bromoform; Bromodichloromethane; Dibromochloromethane)

>99.8%

0.300 +/- 0.30

0.015

TURBIDITY

>99%

11 +/- 1 NTU

0.5 NTU

XYLENES (TOTAL)*

>99%

0.070

0.001

**Percent reduction reflects actual performance of ODAK product as specifically tested (at 200% of capacity, i.e. 1500 gallons).
Percent reduction shown for VOCs* reflects the allowable claims for Volatile Organic Chemicals/Compounds as per Tables.
Chloroform was used as a surrogate for VOC reduction claims; the ODAK Systems actual rate of Chloroform was >99.8% as tested (at 200% of capacity).

NSF/ANSI 42 - Aesthetic Effects

The System has been tested according to NSF/ANSI Standard 42 for the reduction of the following substances. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system.

Substance

Percent Reduction**

Influent Challenge Concentration
(mg/L unless specified)

Maximum Permissible Product Water Concentration
(mg/L unless specified)

CHLOROMINE as Aesthetic Effect (as Monochloramine)

>99%

3.0 mg/L +/- 10%

0.5 mg/L

CHLORINE as Aesthetic Effect

99%

2.0 mg/L +/- 10%

> or = 50%

PARTICULATE (Nominal Particulate Reduction, Class 1, Particles 0.5 TO <1 UM)

Class 1>99%

At least 10,000 particles/mL

> or = 85%

Note: This addresses the U.S. Environmental Protection Agency (EPA) Primary and Secondary Drinking Water Regulations in effect at its time of publication, they relate to Multi-Pure's performance in conformance to the industry performance criteria. These regulations are continually being updated at the Federal level. Accordingly, this list of MCLs will be reviewed and amended when appropriate.

Notes

  1. ODAK Drinking Water Systems have been certified, as indicated, by NSF International for compliance to NSF/ANSI Standard Nos. 42 and 53.

  2. Chloroform was used as a surrogate for claims of reduction of VOCs. ODAK Systems tested at >99.8% actual reduction of Chloroform. Percent reduction shown herein reflects the allowable claims for VOCs as per tables in the Standard.

  3. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

  4. Filter life will vary in proportion to the amount of water used and the level of impurities in the water being processed. For optimum performance, it is essential that the filter be replaced on a regularly scheduled basis as follows: (a) annually; (b) when the unit's rated capacity has been reached; (c) the flow rate diminishes; (d) the filter becomes saturated with bad tastes and odors.

  5. ODAK Drinking Water Systems are warranted for a period of 25 years. All exterior hoses and attachments to the System are warranted for one year. Please see the Owner's Manual for complete product guarantee and warranty information.

  6. Please see the Owner's Manual for installation instructions and operating procedures.

  7. Check for compliance with state and local laws and regulations.

  8. While testing was performed under standard laboratory conditions, actual performance may vary.

  9. The list of substances which the treatment device reduces does not necessarily mean that these substances are present in your tap water.

Home | Corporate Overview | Filter Comparisons | Water Contaminants | Frequently Asked Questions
Performance Data Sheet | Emergency Response | Product Showroom | Kentrel Corporation | Contact ODAK

Web Design by
Harry Finn